In today’s Advisor we focus on some frequently asked questions about electrical safety, with answers provided by OSHA.
What causes electrical shocks?
Electricity travels in closed circuits, normally through a conductor. But sometimes a person’s body—an efficient conductor of electricity—mistakenly becomes part of the electric circuit. This can cause an electrical shock. Shocks occur when a person’s body completes the current path with:
- Both wires of an electric circuit
- One wire of an energized circuit and the ground
- A metal part that accidentally becomes energized
- Another “conductor” that is carrying a current
When a worker receives a shock on the job, electricity flows between parts of the body or through the body to a ground or the earth.
What effect do shocks have on the body?
An electric shock can result in anything from a slight tingling sensation to immediate cardiac arrest. The severity depends on:
- Amount of current flowing through the body
- Current’s path through the body
- Length of time the body remains in the circuit
- Current’s frequency
How can workers tell if a shock is serious?
A severe shock can cause considerably more damage than meets the eye. A victim may suffer internal hemorrhages and destruction of tissues, nerves, and muscles that aren’t readily visible. Renal damage also can occur. If an employee receives a shock, he or she should seek emergency medical help immediately.
Last year OSHA issued thousands of citations for electrical safety violations. BLR’s upcoming live webinar will show you how to avoid common electrical safety mistakes and explain best practices for avoiding OSHA violations and citations. And you don’t even have to leave your office Get the details.
What kind of burns can a shock cause?
Burns are the most common shock-related injury. An electrical accident can result in an electrical burn, arc burn, thermal contact burn, or a combination of burns.
- Electrical burns are among the most serious burns and require immediate medical attention. They occur when electric current flows through tissues or bone, generating heat that causes tissue damage.
- Arc or flash burns result from high temperatures caused by an electric arc or explosion near the body. These burns should be treated promptly.
- Thermal contact burns are caused when the skin touches hot surfaces of overheated electric conductors, conduits, or other energized equipment. Thermal burns also can be caused when clothing catches on fire, as may occur when an electric arc is produced.
In addition to shock and burn hazards, electricity poses other dangers. For example, arcs that result from short circuits can cause injury or start a fire. Extremely high-energy arcs can damage equipment, causing fragmented metal to fly in all directions. Even low-energy arcs can cause violent explosions in atmospheres that contain flammable gases, vapors, or combustible dusts.
Why do people sometimes “freeze” when they are shocked?
When a person receives an electrical shock, sometimes the electrical stimulation causes the muscles to contract. This “freezing” effect makes the person unable to pull free of the circuit. It is extremely dangerous because it increases the length of exposure to electricity and because the current causes blisters, which reduce the body’s resistance and increases the current.
The longer the exposure, the greater the risk of serious injury. Longer exposures at even relatively low voltages can be just as dangerous as short exposures at higher voltages. Low voltage does not imply low hazard.
In addition to muscle contractions that cause “freezing,” electrical shocks also can cause involuntary muscle reactions. These reactions can result in a wide range of other injuries from collisions or falls, including bruises, bone fractures, and even death.
Join us for an in-depth webinar on January 15 when our presenter, a seasoned safety expert who has helped many companies develop compliant electrical safety programs, will suggest ways to improve overall electrical safety compliance. Find out more.
What should employees do if a co-worker "freezes" to a live electrical contact?
If a co-worker is "frozen" to a live electrical contact, employees should shut off the current immediately. If this is not possible, they can use boards, poles, or sticks made of wood or any other nonconducting materials and safely push or pull the person away from the contact. It’s important to act quickly, but employees should remember to protect themselves as well from electrocution or shock.
How is static electricity hazardous?
Static electricity also can cause a shock, though in a different way and generally not as potentially severe as the type of shock described previously. Static electricity can build up on the surface of an object and, under the right conditions, can discharge to a person, causing a shock. The most familiar example of this is when a person reaches for a door knob or other metal object on a cold, relatively dry day and receives a shock.
However, static electricity also can cause shocks or can just discharge to an object with much more serious consequences, as when friction causes a high level of static electricity to build up at a specific spot on an object. This can happen simply through handling plastic pipes and materials or during normal operation of rubberized drive or machine belts found in many worksites.
In these cases, for example, static electricity can potentially discharge when sufficient amounts of flammable or combustible substances are located nearby and cause an explosion. Grounding or other measures may be necessary to prevent this static electricity buildup and the results.
Avoid Electrical Safety Mistakes and Violations
In October 2013, the preliminary figures for OSHA’s top 10 violations for FY 2013 revealed thousands of violations related to electrical safety. Coming in at number five was “electrical, wiring methods” with 3,452 violations. Common issues involved:
- Problems with flexible cords and cables, boxes, and temporary wiring
- Poor use of extension cords
- Using temporary wiring as permanent wiring
At number eight was “lockout/tagout,” with 3,254 violations ranging from poor or no energy control procedures to inadequate worker training, and incomplete inspections. “Electrical, general” took the number nine spot (2,745 violations) for exposure to electric shock and electrocution.
One of the best ways to improve the overall compliance of your safety program is to take a close look at the electrical safety violations for which OSHA is citing companies, including yours. By taking advantage of these “hard lessons learned” you can use the information to identify gaps in your current program and share what you’ve learned with senior management, facility staff, and your audit team.
Join us for an in-depth webinar on January 15 when our presenter, a seasoned safety expert who has helped many companies develop compliant electrical safety programs, will provide participants with an assessment of the FY 2013 electrical violation categories and suggest ways to use the information to improve overall electrical safety compliance.
You and your colleagues will learn:
- Electrical violations on the FY 2013 list and how the electrical safety violation categories relate to OSHA’s 2014 enforcement strategy and initiatives such as the Severe Violators Enforcement Program and the National Emphasis Program
- Approaches you can take for using the electrical safety violations to evaluate your existing compliance status
- How to incorporate this information into your audit and inspection process
- What you can do to stay ahead of OSHA enforcement actions in the area of electrical safety
- The potential impact of new and pending electrical safety regulations and consensus standards such as NFPA70E as they relate to future enforcement trends
- Ways your company can use various data bases such as the electrical violations on the Top 10 to develop your company’s own “Electrical Safety Focus” list
- Why misunderstanding “Arc Flash” can cost money and lives
- The key elements of an electrical safety program
- How can you improve your lockout/tagout program
- Ways to identify and evaluate resources to help you best use this information in a meaningful way
About Your Presenter
Michael Lawrence is principal of Summit Safety Technologies based in Long Beach, California. Mr. Lawrence is an accomplished safety manager and technical trainer, and has been training adult workers and safety professionals for many years. He is a frequent speaker and is recognized for his expert knowledge of safety regulations, safety management systems, business continuation planning, emergency preparedness, and quality management systems.
Mr. Lawrence has more than 30 years experience in safety management, technical training, instructional design, and quality management, with skills that were honed during his 16 years in the semiconductor manufacturing industry and 14 years in Naval Aviation. This experience includes many years in electronics/electrical technology and maintenance. With more than three decades of experience as a frontline worker, supervisor, manager, and business owner, he brings a refreshing down-to-earth approach in the effective sharing of knowledge and experience.
Mr. Lawrence is certified in Safety & Health Systems for Small Business, Instructional Design, and as a Performance Based Equipment Trainer (PBET).
How Do Webinars Work?
A webinar is remarkably cost-effective and convenient. You participate from your office, using a regular telephone and a computer with an Internet connection. You have no travel costs and no out-of-office time.
Plus, for one low price, you can get as many people in your office to participate as you can fit around a speakerphone and a computer screen.
Because the conference is live, you can ask the speakers questions—either on the phone or via the webinar interface.
You will receive access instructions via e-mail three days before the event and the morning of the event. Your conference materials will be included in these emails for you to view, print, and download prior to the event. They are also available on the webinar interface when you log in.
If you are ordering online the morning of the webinar please call our Customer Service Department at 1-800-727-5257 to be sure to get your access instructions and handout materials.